ID | Description |
---|---|
205652 | An error occurs on the Register Input screen when performing the Save action after selecting the License Plate No., if the Inventory/Exp. Date field is not automatically updated. This issue occurs when consuming an item on a production consumption line associated with a machine center that has bin code assigned while using the routing link codes. |
209921 | The Inventory/Exp. Date field on the Register Input screen is incorrectly updated to 1/1/1 as the expiration date when the Use Expiration Dates toggle on the associated Item Tracking Code Card page is turned off. |